UV Sizing Guide.
To accurately size your UV you will need the following information:
- Flow rate
- Target dosage
Often you will not know your target dosage, so we advise a standard dose of 30mj/cm². This dose is high enough to control bacteria and algae. The higher dose of 280mj/cm² is used to control white spot, this is a common aquarium parasite that hobbyists try to target.
Please refer to the table below to appropriately size your unit:
| Model | Lamps/Watts | Connection | UV Dimensions (Length x Diameter) | General Aquarium Volume (L) | Standard Dose (30mJ/cm²) LPM | White Spot Dose (280mJ/cm²) LPM |
|---|---|---|---|---|---|---|
| EU18-U | 1 x 18W | 40mm | 59cm x 10cm | 100 - 300L | 22 | N/A |
| EU25-U | 1 x 25W | 40mm | 74cm x 10cm | 250 - 500L | 35 | N/A |
| EU40 | 1 x 40W | 40mm | 112cm x 10cm | 500 - 1,000L | 58 | 7.6 |
| E50S | 1 x 50W | 50mm | 76cm x 15cm | 800 - 1,500L | 97 | 10 |
| E80S | 1 x 80W | 50mm | 114cm x 15cm | 1,500 - 2,200L | 170 | 18 |
| E120S | 1 x 120W | 50mm | 145cm x 15cm | 2,200 - 4,700L | 242 | 25 |
| E150S-230 | 1 x 150W | 50mm | 180cm x 15cm | 3,500 - 7,500L | 387 | 40 |
| 250240 | 2 x 120W (240W) | 80mm | 158cm x 15cm | 4,500 - 8,200L | 416 | 45 |
| 250300 | 2 x 150W (300W) | 80mm | 193cm x 15cm | 6,500 - 13,000L | 658 | 70 |