Dryden Aqua Oxygen Probe

A galvanic oxygen probe for continuous in-tank dissolved oxygen measurement and control.

Price range: $8.00 through $40.00 ex GST

Product Information

Key Features

  • Galvanic membrane oxygen probe for continuous in-tank measurement, with a high millivolt output suited to PLC-based control
  • Stated accuracy of ±0.2 mg/L, with self-temperature compensation from 5 to 40 °C on both the 2-wire and 5-wire versions
  • Typically 3 to 6 months between calibration checks; maintenance is a weekly wipe of the membrane with a cloth
  • Two membrane types — Teflon for mg/L measurement (supplied as standard) and polythene for % saturation
  • Heavy-duty sub-sea urethane cable into epoxy-sealed internals, rated to 10 atmospheres
  • High output of 6 to 12 mV per mg/L reduces electrical noise problems over long cable runs
  • Optional PT100 temperature sensor built into the probe on the 5-wire version
  • Choosing your model: pick the cable length by how far the probe sits from the controller — 5 m for a tank-side panel, 10 m or 20 m for a remote switchboard — and order Teflon membranes if you read in mg/L or polythene membranes if you read in % saturation. Allow at least 4 cm/s of water movement across the membrane for a valid reading.

Specifications

SpecificationDetailNotes
Dissolved oxygen accuracy±0.2 mg/LMeasuring range and resolution are not published by the supplier
Sensor technologyGalvanic cell — zinc anode, silver cathode, semi-permeable Teflon membraneA membrane sensor: membranes and electrolyte are consumables
Membrane optionsTeflon for mg/L (supplied as standard) or polythene for % saturationTeflon membranes sink, polythene % sat membranes float
Temperature compensationSelf-compensating from 5 to 40 °CApplies to both 2-wire and 5-wire probes
Salinity and barometric compensationContact usHandled by the receiving controller, if at all — confirm before use in seawater
Optional temperature sensorPT100 built into the probe5-wire version; alternative sensors can also be used
Output6 to 12 mV per mg/L (temperature dependent); approximately 80 mV in airHigh output reduces electrical noise over long runs
Calibration intervalTypically 3 to 6 months between checks—
Response timeApproximately 15 to 30 seconds—
Minimum water velocityAt least 4 cm/s across the membraneA membrane sensor consumes oxygen and will read low in still water
Pressure ratingUp to 10 atmospheres—
CableHeavy-duty sub-sea urethane into epoxy-sealed internals; 5 m standard, with 10 m and 20 m optionsExtension with 0.5 mm² multi-strand two-core cable has been tested to 2000 m
Dimensions and weight63 mm diameter × 73 mm long; 1000 g including 5 m cable—
MaintenanceWipe the membrane with a cloth once a week—