UltraAqua ULTRABARRIER™ Intake Water UV Systems

UV systems built as a biosecurity barrier on intake water for aquaculture farms and hatcheries.

Product Information

Key Features

  • Built specifically for aquaculture intake water — a UV firewall that stops pathogens entering the farm rather than a general-purpose disinfection reactor
  • Approved by the Norwegian Veterinary Institute (NVI) for intake water disinfection in aquaculture
  • Delivers the high minimum doses intake duty demands — typically 100 to 300 mJ/cm², many times what routine bacterial control calls for
  • Two DVGW/ÖNORM validated UV sensors continuously regulate and verify the delivered dose, rather than assuming it
  • AISI 316L stainless steel for saline intakes, with a corrosion-free polypropylene option depending on the water source
  • CFD-optimised chambers in an L-configuration — lamps sit closer together, dark zones are eliminated and head loss stays low
  • ULTRAWIPER automated sleeve cleaning built for salt environments; wiper rings change in minutes without tools
  • Full control package: dose pacing, colour touchscreen, per-lamp status LEDs, lifetime monitoring, overheat protection, automatic dimming and SCADA via Modbus
  • Sizing this system: intake UV is sized backwards from biosecurity. Decide the minimum dose your risk profile requires (100 to 300 mJ/cm² is the usual intake band, and a dose adequate for bacteria will not touch a resistant parasite stage), then give us that dose, your design flow and your measured %UVT. The FIREWALL control then holds it — it checks live sensor readings against flow and confirms the flow is low enough to maintain the target minimum dose.

Specifications

ParameterDetail
Minimum UV dose (intake duty)Typically 100 to 300 mJ/cm² — set by the biosecurity risk and the target organism, not by the reactor
Flow capacityNot published by supplier — each system is sized to your flow at your target minimum dose and measured %UVT
Design UVTNot published by supplier — measure yours before sizing; the control system verifies the dose from live sensor readings plus a flow input
Reactor materialAISI 316L stainless steel; corrosion-free polypropylene (PP) option depending on the intake water source
ApprovalNorwegian Veterinary Institute (NVI) approved for intake water disinfection in aquaculture
UV sensorsTwo DVGW/ÖNORM validated sensors (duplex), continuously regulating the UV dose
Reactor designCFD optimised chambers in L-configuration — even dose distribution, minimum head loss, no dark zones
Sleeve cleaningULTRAWIPER automated wiping, built for salt environments; wiper rings replaced in minutes without tools
ControlDose control/pacing, high-resolution colour touchscreen, individual lamp status LEDs, remote or manual operation
MonitoringLamp performance and lifetime monitoring, performance and event log, system state outputs
ProtectionCabinet and reactor overheat protection; up to IP 67; operating temperature up to 70°C
Energy savingAutomatic lamp dimming (power save mode)
CommunicationsSCADA via Modbus
Lamp type and lifeNot published by supplier on this page — confirm at quotation