UV systems built as a biosecurity barrier on intake water for aquaculture farms and hatcheries.
Categories: UV Sterilisers & Spares
Applications: Hatchery, LSS, RAS, Water & Wastewater Treatment
Brand: UltraAqua
| Parameter | Detail |
|---|---|
| Minimum UV dose (intake duty) | Typically 100 to 300 mJ/cm² — set by the biosecurity risk and the target organism, not by the reactor |
| Flow capacity | Not published by supplier — each system is sized to your flow at your target minimum dose and measured %UVT |
| Design UVT | Not published by supplier — measure yours before sizing; the control system verifies the dose from live sensor readings plus a flow input |
| Reactor material | AISI 316L stainless steel; corrosion-free polypropylene (PP) option depending on the intake water source |
| Approval | Norwegian Veterinary Institute (NVI) approved for intake water disinfection in aquaculture |
| UV sensors | Two DVGW/ÖNORM validated sensors (duplex), continuously regulating the UV dose |
| Reactor design | CFD optimised chambers in L-configuration — even dose distribution, minimum head loss, no dark zones |
| Sleeve cleaning | ULTRAWIPER automated wiping, built for salt environments; wiper rings replaced in minutes without tools |
| Control | Dose control/pacing, high-resolution colour touchscreen, individual lamp status LEDs, remote or manual operation |
| Monitoring | Lamp performance and lifetime monitoring, performance and event log, system state outputs |
| Protection | Cabinet and reactor overheat protection; up to IP 67; operating temperature up to 70°C |
| Energy saving | Automatic lamp dimming (power save mode) |
| Communications | SCADA via Modbus |
| Lamp type and life | Not published by supplier on this page — confirm at quotation |
Our team is here to help you find the right equipment for your project.